Avaya 38DHB0002UKDD User Manual

Page 11

Advertising
background image

Software Upgrading and Installation

Installing Software Upgrade - Page 11

Upgrade Steps

Explanation

Step 8
At the debug prompt type the following command:
ipoffice

Step 9
If the previous steps have been followed correctly
and the upgrade is successful thus far to loader
version 1076, an output similar to the following will
be shown.

Tue 27/8/2002 11:30:28, Hello>ipoffice

This is irreversible. Continue (Y/N)?
Press Y on the keyboard.


If the previous steps have been followed
correctly and the upgrade to 1076 is
successful the following output will be shown.

New Boot Sector process
Checking new loader code
New loader code checksum =
0x2EABEEAC, (wanted 0x2EABEEAC)
Saving current feature table
Mac address is 00E007005C27
**********************************

ERASING and PROGRAMMING LOADER

**********************************
**********************************

DONE

**********************************
Tue 27/8/2002 11:31:28, Hello>

Step 10
Reboot the IPNC by typing the following command
at the debug prompt.
reboot
e.g.

Tue 27/8/2002 11:31:28, Hello>

reboot

Step 11
When the IPNC has finished the boot sequence and
the green LED comes on and the Red LED is off,
unplug the IPNC from the INDeX.

Step 12
In order to confirm the IPNC is running the 1.7
Loader image, plug in the IPNC and press ‘Esc’ on
the keyboard within 3 seconds.
The following output will be shown indicating the
upgrade procedure is successful.

P5 Loader 1.7 (2MB-2xF800 Flash-120nS
SDRAM-10)
CPU Revision 0x0502

To quit this mode and continue at the prompt
sequence type: atf


Pressing the ‘Esc’ in this way causes the
IPNC to stop the image load to allow direct
access to the loader mode.

INDeX IPNC Cassette Administration Manual

Software Upgrading and Installation - Page 11

38DHB0002UKDD – Issue 7 (22/11/02)

Installing Software Upgrade

Advertising