Appendix e: cables, Dte cable, Pin connections – Avaya 38DHB0002UKDD User Manual

Page 133

Advertising
background image

Appendix E: Cables

DTE Cable - Page 133

Appendix E: Cables

This section provides information about the cables that are used with IPNC.

All of the following cables are for internal use only.

All structured cabling/site wiring must conform to all local regulations.

CAUTION: All ISDN and WAN cables should not be longer than 5 meters in

length.

DTE Cable

A

B

C

D

A 25 Way (or 9 Way on IP412) D-Type Plug with UNC 4-40 locking screws.
B 9 Way D-Type Socket with UNC 4-40 locking screws.
C 12 core screened cable - each core is 7/0.203mm (24 AWG) tinned copper

stranded wire, nominal capacitance of 95pF/m, resistance of 92

Ω/km,

screened with tinned copper braid, maximum working voltage of 440V rms
and a Maximum current per core of 1A rms

D 2

meters.

Pin Connections

End A (25 Way)

End A (9 Way)

Name

End B

2 3

Receive

data

3

3 2

Transmit

Data

2

4

7

RTS (Request To Send)

7

5

8

CTS (Clear To Send)

8

6

6

DSR (Data Set Ready)

6

7 5

Ground

5

8 1

DCD

(Data

Carrier

Detect)

1

20 4

DTR

(Data

Terminal

Ready)

4

22

9

RI (Ring Indicator)

9

INDeX IPNC Cassette Administration Manual

Appendix E: Cables - Page 133

38DHB0002UKDD – Issue 7 (22/11/02)