1-2

1 Precautions for Installation

1.1 Installation

environment

Install the Scanner in a location, which meets the following requirements to ensure
safe operation and utmost performance.
‹ A place where the illumination onto the book table is less than 1000lx (e.g.

4.5m (15ft)×6.5m (21.5ft) area with ceiling height of 2.6m (8.5ft) and 12 or
less 40W fluorescent lamp.)

‹ A place where the illumination onto the book table is not uneven due to the light

from the lighting system or the outside through windows.

‹ A place away from curtains or other objects that catch fire and burn easily.
‹ A place where there is no possibility of being splashed with water or other

liquid.

‹ An area free from direct sunlight.
‹ A place not in the direct air stream from an air conditioner, heater, and/or

ventilator, ensuring fairly constant temperature.

‹ A well-ventilated place.
‹ A dry place.
‹ A dust-free location.
‹ An area not subject to undue vibration.
‹ A stable and level surface.

1.2 Power

source

The power source voltage requirements are as follows.
‹ Use a power source with little voltage/frequency fluctuations.

Voltage fluctuation:

Up to 120 VAC ±10%, 230 VAC ±10%

Frequency fluctuation: Up to 50 Hz ±3 Hz

Up to 60 Hz ±3 Hz

‹ If any other electrical equipment uses the same power outlet, make sure that the

capacity of the outlet is not exceeded.

‹ The outlet should be located near the Scanner and easily accessible so that

power cord can be pulled out whenever necessary.

‹ NEVER use a multiple adapter to connect other equipment or machines to the

outlet used by the Scanner.

‹ If an extension cord is required, use one with a capacity higher than the power

consumption of the Scanner.

‹ Make sure that no unusual, excessive force is applied to the power cord or

extension cord.