Vertical contact toaster, Troubleshooting(continued) – Antunes, AJ VCT-50 User Manual

Page 16

Advertising
background image

VERTICAL CONTACT TOASTER

16

P/N 1010729 Rev. C 05/04

VERTICAL CONTACT TOASTER

17

P/N 1010729 Rev. C 05/04

TROUBLESHOOTING(continued)

Problem

Possible Cause

Corrective Action

Product is over-toasted

or platen heat is too high

or drop time is too slow.

(continued).

Spring tensioner assy(s). or

tensioner bent or missing.

Replace spring tensioner assy(s). (29, page 20)

or tensioners (4, page 24) if damaged or loose.

Replace slide rails (40, page 24) if worn or missing.

Bun adjustment controls set

incorrectly.

Measure bun thickness and set bun adjustment con-

trols correctly (page 9).

Product is under toasted

or platen heat is too low

or drop time is too fast.

Not enough voltage, defec-

tive power cord, defective

rocker switch.

Confirm platen temperature reading with a pyrometer

or other temperature source.

Check receptacle for correct voltage. See

Specifications (page 5).

With unit plugged in and rocker switch on, check for

correct voltage into rocker switch. If low or zero volt-

age, replace power cord. If voltage is correct, check

for correct voltage out of rocker switch. If low or no

voltage, replace rocker switch.

Wiring problem.

Check all electrical connections for burns, discolor-

ation or arcing. Replace all connections or compo-

nents with damaged terminals. Replace all damaged

wiring with the same (or higher) rated wire.

Platen inoperative.

To check platen:

Use an Ohm meter to test resistance of the platen

heater (disconnect 1 wire to isolate heater). Correct

cold resistance for heating element of platen are as

follows:

120 Volts, 1750 Watts - 7.8 Ohms

208 Volts, 2550 Watts - 16.2 Ohms

230 Volts, 1900 Watts - 26.5 OhmsVCT-20 only. The

auxiliary heaters are 144.2 Ohms at 208V/300 Watts.

Conveyor drive motor inop-

erative or incorrect conveyor

motor installed in toaster.

To check drive motor:

1. Measure resistance of motor coil. Replace motor

if coil measures either open circuit or zero resis-

tance.

2. Mark the drive motor sprocket and count the turns

per minute. Correct drive motor speed is nine (9)

turns per minute for VCT-20; three (3) turns per

minute for VCT-25; one (1) turn per minute for

VCT-50.

Product is getting stuck

or conveyor belts stop

when product is toasting.

Bun adjustment controls set

incorrectly.

Measure bun thickness and set bun adjustment con-

trols correctly (page 9).

Conveyor release sheet not

clean or missing.

Clean respective items. Refer to Maintenance

Schedule (page 10).

Advertising