Problem

Possible Cause

Corrective Action

Product is getting stuck

or conveyor belts stop

when product is toasting

(continued).

Not enough voltage, defec-

tive power cord or rocker

switch.

Check receptacle for correct voltage. See

Specifications (page 5).

With unit plugged in and rocker switch on, check for

correct voltage into rocker switch. If low or zero volt-

age, replace power cord. If voltage is correct, check

for correct voltage out of rocker switch. If low or no

voltage, replace rocker switch.

Wiring problem.

Check all electrical connections for burns, discolor-

ation or arcing. Replace all connections or compo-

nents with damaged terminals. Replace all damaged

wiring with the same (or higher) rated wire.

Conveyor drive motor inop-

erative or incorrect conveyor

motor installed on toaster.

To check drive motor:

1. Measure resistance of motor coil. Replace motor

if coil measures either open circuit or zero resis-

tance.

2. Mark the drive motor sprocket and count the turns

per minute. Correct drive motor speed is nine (9)

turns per minute for VCT-20; three (3) turns per

minute for VCT-25; one (1) turn per minute for

VCT-50.

Conveyor drive chain loose,

worn or broken. Loose

motor drive sprocket.

Check drive chain for kinks, broken or bent links

or other damage. Check motor sprocket and drive

sprockets (on drive shaft); tighten setscrew on flat of

shaft if required. Check for damaged/worn sprockets

and replace as required.

Conveyor cover assy(s).

not installed, or improperly

installed.

Install conveyor cover assy(s).

Conveyor belts installed

incorrectly.

Install conveyor belt to match diagram in Fig. 8 (page

11). Be sure that ends of the hooks are facing down.

Conveyor belt too loose

or missing links (41 links

required when new). When

new, conveyor has 37 large

links and 4 small links.

Remove conveyor belt (page 11). Lay belt flat and

count links. Replace entire belt if links are dam-

aged. If conveyor belt has too much play, it will jam.

Adjust belt length as described under Servicing the

Conveyor Belt (page 11).

Spring tensioner assy(s). or

tensioner bent or missing.

Replace spring tensioner assy(s). (29, page 22)

or tensioners (4, page 24) if damaged or loose.

Replace slide rails (40, page 24 worn or missing.