AEG L61271WDBI User Manual

Page 20

Advertising
background image

A

B

3.

Place a container close to the pump
to collect any spillage.

4.

Release the emergency emptying
hose (B), place it in the container
and remove its cap cover.

5.

When no more water comes out,
unscrew the pump cover (A) by turn-
ing it anti-clockwise and remove the
filter. Use pliers, if necessary.
Always keep a rag nearby to dry up
any water spillages when removing
the cover. Clean the filter under a
tap, to remove any traces of fluff.

6.

Remove foreign bodies and fluff
from the filter seat and from the
pump impeller.

7.

Check carefully whether the pump
impeller rotates (it rotates jerkily). If
it doesn’t rotate, please contact
your Service Centre.

20 www.aeg.com