Troubleshooting, 8 emergency emptying out, 9 frost precautions – AEG L61271WDBI User Manual

Page 22

Advertising
background image

45°

20°

6.

Install again the inlet hose. Make
sure that the couplings are tight to
prevent leakages.

7.

Open the water tap.

11.8 Emergency emptying out

If the water is not discharged, proceed
as follows to empty out the appliance:

1.

pull out the plug from the power
socket;

2.

close the water tap;

3.

if necessary, wait until the water has
cooled down;

4.

place a bowl on the floor;

5.

place the end of the emergency
emptying hose into the bowl;

6.

Remove its cap. The water should
drain by gravity into the bowl. When
the bowl is full, put the cap back on
the hose. Empty the bowl;
Repeat the procedure until water
stops flowing out;

7.

clean the pump if necessary as previ-
ously described;

8.

replace the emergency emptying
hose in its seat after having plugged
it;

9.

screw the pump again.

11.9 Frost precautions

If the machine is installed in a place
where the temperature could drop be-
low 0°C, proceed as follows:

1.

close the water tap;

2.

unscrew the water inlet hose from
the tap;

3.

place the end of the emergency
emptying hose and that of the inlet
hose in a bowl placed on the floor.
Let water drain out;

4.

screw the water inlet hose back on;

5.

put the cap on the emergency emp-
tying hose again;

6.

reposition the emergency emptying
hose.

By doing this, any water remaining in the
machine is removed, avoiding ice form-
ing and consequently damage to the ap-
pliance.
When you use the machine again, make
sure that the ambient temperature is
above 0°C.

12. TROUBLESHOOTING

Certain problems are due to lack of sim-
ple maintenance or oversights, which
can be solved easily without calling out
an engineer. Before contacting your lo-
cal Service Centre, please carry out the
checks listed below.
During machine operation it is possible
that the yellow pilot light of button 8
blinks, one of the following alarm codes
appears on the display and at the same
time some acoustic signals sound every
20 seconds to indicate that the machine
is not working:

: problem with the water supply

: problem with the water drain-

ing

: door open

: anti-flooding system has activa-

ted

Once the problem has been eliminated,
press the button 8 to restart the pro-
gramme. If after all checks, the problem
persists, contact your local Service Cen-
tre.

22 www.aeg.com