2 atto ipbridge 2700c physical components, Dimensions, Width – ATTO Technology 2700C User Manual

Page 10: Length, Height of tallest component, Environment, Operating temperature, Ambient air, User-configurable thermal sensor, Humidity

Advertising
background image

5

ATTO Technology Inc. iPBridge Installation and Operation Manual

1.2 ATTO iPBridge 2700C physical components

The ATTO iPBridge 2700C is a 1-Gigabit Ethernet to Fibre Channel embeddable cPCI bridge for high
performance, cost effective solutions in enterprise environments.

Dimensions

Width:

6.193 inches

Length:

6.299 inches

Height of tallest component:

.545 inches

Environment

Operating Temperature:

5-40 °C external

Ambient air:

should not exceed 40 °C

User-configurable thermal sensor

for automatic

shutdown. Default is 70 °C

Humidity:

10-90% non-condensing

Recommended airflow:

166.25 LFM

Power
The iP2700C
board may be
powered from
the cPCI
backplane
connector or a 6-pin connector.

Input voltage:

5.0V

Power draw:

30 Watts

Battery-backed event log SRAM & Real-Time-
Clock:

A rechargeable Lithium ion battery cell

will hold the memory in a 512KB SRAM for up to
30 days.

WARNING

Risk of explosion if the battery is removed
and/or replaced by an incorrect type.
Dispose of used batteries in accordance
with your local environmental regulations.

If the iPBridge becomes disconnected from
power, recharging begins automatically when
power is restored to the system. The battery is
fully charged after 24 hours of continuous power
application.

Ethernet interface
The four independent 100/1000 Ethernet RJ-45
data ports are labeled Ethernet ports 1, 2, 3 and 4.

The data ports support IP v.4 in compliance with
IEEE 802.3 GbE. Each may be used for iPBridge
management. GbE cables must be at least CAT-
5E certified.

Fibre Channel interface
The two independent optical SFP 4-Gb Fibre
Channel ports auto-negotiate to 1-, 2- or 4-Gigabit
devices.

Management ports
A 100 Mb/sec.
Ethernet standard
RJ-45 management
port and a serial 10-
pin header provide
support for remote
monitoring and
management. The serial port is set at the factory at
115,200 bps.

Reset/restore factory default switch
To reset the iPBridge, briefly insert a tool in the
hole in the back panel for less than three seconds.
See Exhibit 1.2-1.
To restore factory defaults, insert the tool in the
hole in the back panel for more than four seconds
until the green Ready LED blinks.

LED indicators
On-board LED indicators show through the
faceplate and follow left to right. See Exhibit 1.2-
1.

Fibre Channel ports:

A lighted green LED

indicates link; off means no link. A separate green
LED indicates activity if it is lit, no activity if it is
off.

Gigabit Ethernet ports:

a green light on the

bicolor LED indicates 100 Mb/sec. Ethernet
speed while a lighted yellow LED shows 1000

4

5

2

1

3

6

NU 5V GND 5V 5V GND

6-pin connection pinouts

Advertising