Maxburstlength, Maxrecvdatasegmentlength, Maxtransferlength – ATTO Technology 2700C User Manual

Page 31: Srbtimeoutdelta, Tcp1323opts, Reset/restore factory default

Advertising
background image

26

MaxBurstLength
The maximum data payload, in bytes, in a Data-In or a
solicited Data-Out iSCSI sequence. A sequence consists
of one or more consecutive Data-In or Data-Out PDUs
that end with a Data-In or Data-Out PDU with the F bit
set to one.

ATTO value: 1048576 decimal 00100000 hex

MaxRecvDataSegmentLength
The maximum data segment length, in bytes, that a
transmitter (initiator or target) can receive in an iSCSI
PDU. The transmitter is required to send PDUs with a
data segment that does not exceed
MaxRecvDataSegmentLength of the receiver.

ATTO value: 1048576 decimal 00100000 hex

MaxTransferLength
The maximum number of bytes that may be transferred by
a single request block (SRB).

ATTO value 1048576 decimal 00100000 hex

SrbTimeoutDelta
The maximum amount of time, in seconds, before an SRB
request will time out.

ATTO value 300 decimal 0000012c hex

Tcp1323Opts
This parameter controls RFC 1323 time stamps and
window-scaling options. Time stamps and window
scaling are enabled by default, but can be manipulated
with flag bits. Bit 0 controls window scaling and bit 1
controls time stamps.

ATTO value: 1

Reset/restore factory default

To reset the iPBridge, briefly insert a tool in the
hole in the back panel for less than three seconds.
See Exhibit 6.0-1.

To restore factory defaults, insert the tool in the
hole in the back panel for more than four seconds
until the green Ready LED blinks.