E-28 – Olympus PT-014 User Manual

Page 29

Advertising
background image

Install the O-ring.

Confirm that no foreign matter is attached, apply a thin coat of the accessory
grease to the O-ring, and fit the O-ring into the groove. At this time, confirm
that the O-ring does not stick out from the groove.

E-28

:・When a mechanical pencil or a similar other sharp object is

used to remove the O-ring or to clean the inside of the O-
ring groove, the Case and the O-ring may be damaged and
water leakage may be caused.

・ When the O-ring is checked with the fingertips, take care not

to stretch the O-ring.

・ Never use alcohol, thinner, benzene or similar solvents or

chemical detergents to clean the O-ring. When such
chemicals are used, it is to be feared that the O-ring will be
damaged or that its deterioration will be accelerated.

CAUTION

Use a clean cloth not easily shedding fibers or a toothbrush or tissue paper or
the like to remove any foreign matter from the O-ring groove. Clean the O-ring
contact surface on the front lid in the same way to remove any sand and dirt.