Other external fl ash units, Information, 110 en – Olympus E-PM2 User Manual

Page 110: Wireless fl ash control range, Cautions

Advertising
background image

110 EN

Information

10

3

Adjust the settings for each group in the super control panel.

Flash intensity

value

250

250 F5.6 0.0

0.0

P

38

38

A Mode

TTL

M

Off

+5.0

TTL

+3.0

1/8

LO

1

Ch

Group

• Select the fl ash control

mode and adjust the fl ash
intensity separately for
each group. For MANUAL,
select the fl ash intensity.

Normal fl ash/Super FP fl ash

• Switch between normal

fl ash and Super FP fl ash.

Communication light level

• Set the communication

light level to [HI], [MID],
or [LO].

Channel

• Set the communication

channel to the same
channel used on the fl ash.

Flash
intensity

Flash control

mode

Adjust settings for the
camera fl ash unit.

4

Attach the supplied fl ash unit and raise the fl ash head.

• After confi rming that the built-in and remote fl ash units have charged, take a test shot.

Wireless fl ash control range

Position the wireless fl ash units with their remote sensors facing the camera. The following
illustration shows the approximate ranges at which the fl ash units can be positioned. The
actual control range varies with local conditions.

7m

5m

100°

100°

50°

50°

50°

50°

60°

60°

30°

30°

30°

30°

#

Cautions

• We recommend using a single group of up to three remote fl ash units.
• Remote fl ash units cannot be used for second curtain slow synchronization or anti-shock

exposures longer than 4 seconds.

• If the subject is too close to the camera, the control fl ashes emitted by the supplied fl ash

may affect exposure (this effect can be reduced by reducing the output of the supplied
fl ash by, for example, using a diffuser).

• The upper limit of fl ash synchronization timing is 1/160 sec. when using the fl ash in

remote control mode.

Other external fl ash units

Note the following when using a third-party fl ash unit mounted on the camera hot shoe:

• Using obsolete fl ash units that apply currents of more than about 24 V to the camera hot

shoe X-contact will damage the camera.

• Connecting fl ash units with signal contacts that do not conform to Olympus specifi cations

may damage the camera.

• Use only with the camera in shooting mode M at shutter speeds slower than 1/160 s and

at ISO settings other than [Auto].

• Flash control can only be performed by manually setting the fl ash to the ISO sensitivity

and aperture values selected with the camera. Flash brightness can be adjusted by
adjusting either ISO sensitivity or aperture.

• Use a fl ash with an angle of illumination suited to the lens. Angle of illumination is usually

expressed using 35-mm format equivalent focal lengths.