Video, Additional information 12 – Pioneer VSX-1019AH-K User Manual

Page 105

Advertising
background image

Additional information

12

105

En

Video

Symptom

Remedy

No image is output when an
input is selected.

• Check the video connections of the source component (see page 28).
• For HDMI, or when digital video conversion is set to OFF and a TV and another
component are connected with different cords (in Setting the Video options on
page 66), you must connect your TV to this receiver using the same type of video
cable as you used to connect your video component.
• Make sure the input assignment is correct for components connected using
component video or HDMI cables (see The Input Setup menu on page 39).
• Check the video output settings of the source component.
• Check that the video input you selected on your TV is correct.
• Some components (such as video game units) have resolutions that may not
be converted. If adjusting this receiver’s Resolution setting (in Setting the Video
options
on page 66) and/or the resolution settings on your component or
display doesn’t work, try switching Digital Video Conversion (in Setting the Video
options
on page 66)

OFF.

Can’t record video.

• Check that the source is not copy-protected.
• The video converter is not available when making recordings. Check that the
same type of video cable is used for connecting both the recorder and the video
source (the one you want to record) to this receiver.

Noisy, intermittent, or
distorted picture.

• Sometimes a video deck may output a noisy video signal (during scanning,
for example), or the video quality may just be poor (with some video game units,
for example). The picture quality may also depend on the settings, etc. of your
display device. Switch off the video converter and reconnect the source and
display device using the same type of connection (component or composite),
then start playback again.

Video signals are not output
from the component
terminal.

• When a monitor only compatible with resolutions of 480i is connected to the
component terminal and another monitor is connected to the HDMI terminal,
the video signals may not be output to the monitor connected to the component
terminal. If this happens, do the following:
– Turn off the power of the monitor connected to the HDMI terminal.
VSX-1019AH model: Set RES on the VIDEO PARAMETER menu to PURE
(page 66).
VSX-919AH model: Set IP CONV on the VIDEO PARAMETER menu to OFF
(page 66).

VSX-1019_SVYXJ.book 105 ページ 2009年2月17日 火曜日 午前11時13分

Advertising