The advanced mcacc menu 10, Using acoustic calibration eq professional – Pioneer VSX-1019AH-K User Manual

Page 86

Advertising
background image

The Advanced MCACC menu

10

86

En

Using Acoustic Calibration EQ Professional

1

Select ‘EQ Professional’, then press ENTER.

2

Select an option and press ENTER.

Reverb Measurement – Use this to

measure the reverb characteristics of your
room.

Reverb View – You can check the reverb

measurements made for specified
frequency ranges in each channel.

1

Advanced EQ Setup – Use this to select

the time period that will be used for
frequency adjustment and calibration,
based on the reverb measurement of your
listening area. Note that customizing
system calibration using this setup will
alter the settings you made in
Automatically setting up for surround
sound (Auto MCACC)
on page 37 or
Automatic MCACC (Expert) on page 77 and
is not necessary if you’re satisfied with
these settings.

3

If you selected ‘Reverb Measurement’,

select EQ ON or OFF, and then START.

The following options determine how the
reverb characteristics of your listening area are
displayed in Reverb View:

EQ OFF – You will see the reverb

characteristics of your listening area
without the equalization performed by this
receiver (before calibration).

EQ ON – You will see the reverb

characteristics of your listening area with
the equalization performed by this receiver
(after calibration).

2

Note that the EQ

response may not appear entirely flat due
to adjustments necessary for your listening
area.

3

When the reverb measurement is finished, you
can select Reverb View to see the results on-
screen. See Professional Calibration EQ
graphical output
on page 107 for
troubleshooting information.

Note

1 If the Reverb View procedure is performed after the Automatically setting up for surround sound (Auto MCACC) on

page 37 or Reverb Measurement operation, depending on the standing wave control setting, differences may
appear on the reverb graph. With the Auto MCACC function, the reverberations are measured with the standing waves
controlled, so the reverb characteristics graph shows the characteristics with the effect of the standing waves
eliminated. By contrast, the Reverb Measurement function measures the reverberations without controlling the
standing waves, so the graph indicates the reverb characteristics including the effect of the standing waves. If you
wish to check the reverb characteristics of the room itself (with the standing waves as such), we recommend using
the Reverb Measurement function.

1. Fine Channel Level
2. Fine SP Distance
3. Standing Wave

1c.Manual MCACC

4. EQ Adjust

5. EQ Professional

A/V RECEIVER

Exit

Return

a. Reverb Measurement

b. Reverb View
c. Advanced EQ Setup

1c5.EQ Professional

A/V RECEIVER

Exit

Return

2 The calibration corresponding to the currently selected MCACC preset will be used when EQ ON is selected. To use

another MCACC preset, exit the HOME MENU and press MCACC to select it before pressing HOME MENU.

3 After auto calibration with EQ Type : SYMMETRY (Full Auto MCACC, etc.), the graph for the inferred reverb

characteristics can be displayed by selecting Reverb View. To display the actually measured reverb characteristics
after EQ calibration, measure with EQ ON.

MCACC :

M1.MEMORY 1

1c5a.Reverb Measurement

A/V RECEIVER

Exit

Cancel

START

Reverb Measure with :

EQ OFF

VSX-1019_SVYXJ.book 86 ページ 2009年2月17日 火曜日 午前11時13分

Advertising
This manual is related to the following products: