Engines give off carbon monoxide, an odorless, colorless, poison gas.
Breathing carbon monoxide can cause nausea, fainting or death.

WARNING

Start and run engine outdoors.

Do not start or run engine in enclosed area, even if doors or windows are open.

NOTICE: This engine was shipped from Briggs & Stratton without oil. Before you start

the engine, make sure you add oil according to the instructions in this manual. If you

start the engine without oil, it will be damaged beyond repair and will not be covered

under warranty.
Note: Some engines and equipment have remote controls. See the equipment manual

for location and operation of remote controls.
1. Check the oil level. See the How To Check/Add Oil section.
2. Make sure equipment drive controls, if equipped, are disengaged.

3. Turn the fuel shut-off valve (A), if equipped, to the on

position (Figure 4).

4. Move the throttle control (B) to the fast

position. Operate the engine in the fast

position.

5. Move the choke control (C), or the combination choke/throttle lever, to the choke

position.

Note: Choke is usually unnecessary when restarting a warm engine.

6. Rewind Start: Turn the key switch (D) to the run position.
7. Rewind Start: Firmly hold the starter cord handle (E). Pull the starter cord handle

slowly until resistance is felt, then pull rapidly.
Note: If the engine does not start after repeated attempts, go to

BRIGGSandSTRATTON.COM or call 1-800-233-3723 (in USA).

WARNING:

Rapid retraction of the starter cord (kickback) will pull your

hand and arm toward the engine faster than you can let go. Broken bones, fractures,

bruises or sprains could result. When starting engine, pull the starter cord slowly until

resistance is felt and then pull rapidly to avoid kickback.

8. Electric Start: Turn the electric start switch (D) to the on/start position.

Note: If the engine does not start after repeated attempts, go to

BRIGGSandSTRATTON.COM or call 1-800-233-3723 (in USA).
NOTICE: To extend the life of the starter, use short starting cycles (five seconds

maximum). Wait one minute between starting cycles.

9. As the engine warms up, move the choke control (C) to the run

position.

How To Stop The Engine - Figure 4

WARNING

Gasoline and its vapors are extremely flammable and explosive.
Fire or explosion can cause severe burns or death.

When Starting Engine

Do not choke the carburetor to stop engine.

1. With the throttle control in the fast

position, turn the key switch (D) to the off

position (Figure 4).

2. After the engine stops, turn the fuel shut-off valve (A), if equipped, to the closed

position.

Maintenance

Use only original equipment replacement parts. Other parts may not perform as

well, may damage the unit, and may result in injury. In addition, use of other parts

may void your warranty.
We recommend that you see any Briggs & Stratton Authorized Dealer for all

maintenance and service of the engine and engine parts.
NOTICE: All the components used to build this engine must remain in place for proper

operation.

Emissions Control

Maintenance, replacement, or repair of the emissions control devices and systems

may be performed by any non-road engine repair establishment or individual.

However, to obtain “no charge” emissions control service, the work must be performed

by a factory authorized dealer. See the Emissions Warranty.

Unintentional sparking can result in fire or electric shock.
Unintentional start-up can result in entanglement, traumatic

amputation, or laceration.
Fire hazard

WARNING

Before performing adjustments or repairs:

Disconnect the spark plug wire and keep it away from the spark plug.

Disconnect battery at negative terminal (only engines with electric start.)

Use only correct tools.

Do not tamper with governor spring, links or other parts to increase engine

speed.

Replacement parts must be the same and installed in the same position as the

original parts.

Do not strike the flywheel with a hammer or hard object because the flywheel

may later shatter during operation.

When testing for spark:

Use approved spark plug tester.

Do not check for spark with spark plug removed.

Maintenance Chart

First 5 Hours

Change oil

Every 8 Hours or Daily

Check engine oil level

Clean area around muffler and controls

Clean finger guard (if equipped)

Every 25 Hours or Annually

Clean air filter *

Clean pre-cleaner *

Every 50 Hours or Annually

Change engine oil

Replace oil filter (if equipped)

Check muffler and spark arrester

Annually

Replace air filter

Replace pre-cleaner

Replace spark plug

Clean air cooling system *

Replace fuel filter

Check valve clearance **

*

In dusty conditions or when airborne debris is present, clean more often.

** Not required unless engine performance problems are noted.

Carburetor Adjustment

Never make adjustments to the carburetor. The carburetor was set at the factory to

operate efficiently under most conditions. However, if adjustments are required, see a

Briggs & Stratton Authorized Dealer for service.
NOTICE: The manufacturer of the equipment on which this engine is installed specifies

the top speed at which the engine will be operated. Do not exceed this speed.

How To Replace The Spark Plug - Figure 5

Check the gap (A, Figure 5) with a wire gauge (B). If necessary, reset the gap. Install

and tighten the spark plug to the recommended torque. For gap setting or torque, see the

Specifications section.
Note: In some areas, local law requires using a resistor spark plug to suppress ignition

signals. If this engine was originally equipped with a resistor spark plug, use the same

type for replacement.

Not for Reproduction