Vacuum cleaner won't run.

possible causes

Remedies

1. Power cord not firmly plugged in

1. Check electrical plug

2. Thermal protector activated

2. Allow cleaner to cool for 30 minutes,

see pg. 15

no power at rotating floor brush.

possible causes

Remedies

1. Cylinder is not securely seated

1. Remove cylinder and replace, making sure

that it “clicks” into place

2. Brush switch turned to off

(O)

2. Make sure brush switch is in on

(I)

position

3. Vacuum is in upright position

3. Recline vacuum to operate brush

Vacuum cleaner or tools won't pick up dirt.

possible causes

Remedies

1. Incorrect height adjustment

1. Adjust powerfoot to correct height setting

2. Hose not attached to suction opening

2. Grasp hose grip and firmly push onto the base

3. Crack or hole in hose

3. Check hose and replace if needed

4. Drive belt broken, worn or off motor pulley

4. Reposition or replace drive belt, see pg. 12

5. Rotating floor brush bristles worn

5. Replace brush

6. Rotating floor brush jammed

6. Remove brush and clean debris from

brush ends

7. Clog in vacuum

7. Follow instructions on pg. 14 for clearing clogs

8. Dirt container full

8. Empty dirt container

9. Dirt container or upper tank not installed properly

9. Position correctly and lock in place

10. Filters are dirty

10. Check and clean or replace upper tank,

pre-motor and post-motor filters