For example, to configure Port 2 in the non-verbose mode at 300
baud rate, 7 bit word size, 2 stop bits, even parity, XON/XOFF
enabled, line feed terminating character, data block length 250,
control character

Control-T

, mode of operation 6, and XON/XOFF

enabled, send the following character string:

^TI^TC22*233343526Y130A4250*51466X.

This breaks down as follows:

^T indicates control character.
I indicates non-verbose mode.
^T indicates control character.
C indicates Configuration Mode.
2 indicates Set Serial Port Configuration.
2 indicates Port 2.
* indicates

Carriage Return.

2 indicates Set Baud Rate.
3 indicates 300 Baud.
3 indicates Set Word Size.
3 indicates 7 Word Size.
4 indicates Set Stop Bits.
3 indicates 2 Stop Bits.
5 indicates Set Parity.
2 indicates Even Parity.
6 indicates Set XON/XOFF.
Y indicates XON/XOFF enabled.
1 indicates Exit to Main Menu.
3 indicates Set Message Terminate Character.
0A indicates Line Feed Terminating Character in Hex.
4 indicates Set Data Block Length.
250 indicates Data Block Length.
* indicates

Carriage Return

.

5 indicates Set Control Character.
14 indicates

Control-T

in HEX.

6 indicates Set Mode of Operation.
6 indicates Mode of Operation 6.
X indicates Exit to Operation Mode.

Advertising