Liebherr MKv 3910 User Manual

Page 5

Advertising
background image

17

GB

Symbols in the display

Compressor is running

LED flashing - refrigeration unit switches on after a delay. The

compressor will start automatically after the pressure in the

refrigerant circuit has equalised.

Fan is running

Appliance is defrosting

AUX

Temperature display using reference sensor

Interior light is switched on (MKv 3913)

Alarm function

If

appears in the display, the appliance has a fault. Consult

your nearest customer service point.

HACCP

(Hazard Analysis Critical Control Point)

The

HACCP display means that the power supply and

interior temperature of the appliance are recorded.

If

HACCP flashes in the display, there has either been a

power failure or the temperature in the appliance exceeded

the permissible range.

Operating and control elements

1

ON/OFF

button (to switch the appliance on and off)

2

Selection buttons

3

Set

button (Enter)

4

Audible warning

on/off button

5

Button for calling up stored alarm events

6

Temperature display

7

Interior light on/off button (MKv 3913)

Interior temperature

The temperature inside the appliance is set to +5°C (+/-3K) as

required by DIN 58345 and cannot be changed.

Important note

Items must not be stored in the appliance until

the temperature has reached 5°C.

Electrical connection

Only operate the appliance with alternating current (AC).

The permissible voltage and frequency are indicated on the type

plate. The position of the type plate is shown in the section entitled

Description of the appliance.

The socket must be properly earthed and protected by a fuse.

The tripping current of the fuse must be between 10 A and 16 A.

The socket must not be situated behind the appli-

ance and must be easily accessible.

Do not connect the appliance using an exten-

sion cable or extension socket.

Do not use stand-alone inverters (conversion

of direct current to alternating/three-phase

current) or energy-saving plugs. Risk of dam-

age to the electronic control system!

• Connect the appliance to the

mains - the display reads OFF.

Note

It will take 24 hours for the batteries in the power failure

alarm to become fully charged.

Instructions for decommissioning the appliance

When decommissioning the appliance, it is essential

to follow the instructions in the section entitled "Shut-

ting your appliance down".

Otherwise, the power failure alarm will be activated

when the mains plug is disconnected.

Advertising