18

Door open alarm

When the door is opened, the LED lights up and the tempera-

ture display begin to flash.

When the door has been left open for more than 60 seconds, the

LED begins to flash, and

and the temperature indication

flash alternately in the display.

The audible warning signal sounds.

If the door has to stay open for longer in order to insert items to be

cooled, cancel the audible warning signal by pressing button

.

Setting the delay time for the door open alarm

The time before the audible warning signal sounds after the door

has been opened can be adjusted.

Press

for 5 seconds. Display =

Display =

Display = (minute)

Setting range = 1 - 5 minutes

Use buttons

and

to select the desired setting.

Display =

Press

for 5 seconds.

The electronic control system will switch back to normal operat-

ing mode.

Audible warning signal

The audible warning signal will sound in certain alarm events.

It can be cancelled by pressing button

.

Switching the appliance on and off

Switching the appliance on

Keep the ON/OFF button

pressed for approx. 5 seconds - the

display reads ON.

No alarm is displayed or sounded when the appliance is switched

on for the first time.

If the appliance is disconnected from the mains for a long time after

it has been switched on for the first time and if the temperature

inside the appliance rises above the upper alarm limit, this will

be detected as a fault by the electronic control system (HACCP

appears in the display).

When the appliance is switched on again, this display must be

reset as shown below.

Press button

.

Press

+

for 5 seconds. The display will read

.

The HACCP LED will now light up permanently.

Press

for 5 seconds.

The electronic control system will switch back to normal operat-

ing mode.

Switching the appliance off

Keep the ON/OFF button

pressed for approx. 5 seconds - the

display reads OFF.

Power failure alarm

In the case of a power failure, the

audible warning signal will sound

and

will be shown in the

display.

If HACCP appears in the refrigerator’s display, the

temperature has risen above the upper alarm limit

of + 8°C.

Check the temperature progression as described in the section

entitled

Calling up stored alarm events

and then make a decision on what you wish to do with the items

stored in the refrigerator.

Advertising