New Buck Corporation 20 Room Heater User Manual

Page 26

Advertising
background image

4. Thoroughly clean the fireplace of ashes and soot.
5. Check the chimney and smoke chamber for excessive buildup of creosote or soot. Also, check for

obstructions, such as birds’ nest. If the chimney is excessively dirty, clean it, or have someone clean it
professionally BEFORE installing or using the room heater.

6. The Firebrick, Ash Lip, Smoke Baffle, and Smoke Shelf may also be removed if necessary to provide room

for the Model 20.



CAUTION: Any parts removed from the Pre-Fab Fireplace must be stored inside the unit or given to the

homeowner for re-installation should the Model 20 be removed.


Heater Preparation

1. Inspect the unit for any obvious physical damage.

2. Plug the power cord into a 115V AC outlet. Set switch to “Manual” and rheostat to “High” position to ensure

motor operates properly.


3. Check the primary air draft control to ensure that it operates freely.

4. Check the operations of the damper control to ensure that it will open and close properly.



Heater Installation


1. There are three listed and tested methods of installation of the Model 20 heater into the specified Pre-Fab

Models.

A. 6”

Increaser


1. The preferred method is to use an increaser made of 24 ga. (minimum) stainless steel to go from 6”

inside diameter to the exact diameter of the fireplace throat/chimney. (See Figure 2.)


2. Position the increaser into the throat/chimney of the Pre-Fab Cabinet at a height slightly higher than

the Model 20 will be after installation (22” + above Pre-Fab heater supports). NOTE: The increaser may

be a two part slip connector type if desired.


B. Ceramic

Blanket


1. The second method is to use a 6” stainless steel connector (rigid or flex) and a ceramic blanket

(available from your dealer). (See Figure 3.)


2. Cut the connector at least 18” long and tightly wrap the upper portion of the connector with the

ceramic blanket to almost the size of the fireplace throat/chimney.


3. Insert the connector into the fireplace throat/chimney and use additional ceramic insulation and tightly

pack around the connector and the throat/chimney at a height slightly higher than the Model 20 will be

after installation (22” + above Pre-Fab heater supports). NOTE: The increaser may be a two part size

connector type if desired.