6. Obtain the listed and approved chimney installation instructions and follow exactly.

a) Obtain the starter section of pipe and install on the ZC20 cabinet. It may be necessary to crimp the inside

of the starter pipe to ease installation into the ZC20 cabinet.

b) Obtain the two short sheet metal “ell” brackets and sheet metal screws provided with the ZC20 and secure

the starter section of pipe to the ZC20 cabinet.

































c) Continue adding lengths of chimney until you are ready to penetrate another ceiling or the roof.
d) Now, plumb bob the center of the ceiling or roof above the chimney and install another firestop for

another ceiling penetration or follow pipe manufacturer’s instructions for attic and roof penetration.

e) Once the roof penetration is made, install the flashing.
f) Add applicable lengths of chimney, extending through the roof until the following conditions are met:
1. Chimney height is at least 12’ to 15’ maximum.
2. The chimney must extend a minimum of 3’ above the highest point where it penetrates the roof.
3. The chimney must extend a minimum of 2’ higher than any portion of the building within 10’ of the
chimney.
g) Install

the

chimney

cap and storm collar.

Install pipe to cabinet by pushing
down over the starter section of pipe
on the ZC cabinet.

Maintain a 2” minimum
clearance

Top Standoffs

CAUTION: Maintain a 3/4” air
space between the back and 1 1/2”
between the side walls and
combustible material.

WARNING: Do not pack

required air spaces on top of cabinet
or around pipe starter section with
insulation or other materials.

Figure 5