F. DO NOT build a fire directly inside the ZC Cabinet. It is designed solely for housing the Model 20 Stove.

G. WARNING: This fireplace has not been tested for use with a chase above the roof.

H. Do not connect this unit to a chimney serving another appliance.

SELECTING A CHIMNEY INSTALLATION AND LOCATION

There are two basic types of chimney installations possible with the ZC20; straight up through a ceiling, and chase
installation, either outside or inside. These are normally used as follows:











FIGURE 1 THROUGH CEILING

FIGURE 2 THROUGH CATHEDRAL
CEILING

FIGURE 3 OFFSET TO CLEAR OBSTRUCTION

CAUTION: Refer to chimney
manufacturers instructions for assembly

and disassembly of chimney parts. Be sure to
follow chimney instructions for proper clearances
to combustibles and proper air spacing required.

STORM COLLAR

FLASHING

CHIMNEY PIPE

METAL FIRE STOP

METAL FIRE STOP

Z.C. CABINET

CHIMNEY CAP

CHIMNEY CAP

CHIMNEY PIPE

STORM COLLAR

FLASHING

METAL FIRE STOP

Z.C. CABINET

CHIMNEY CAP

CHIMNEY PIPE

STORM COLLAR

FLASHING

ELBOWS

ADJUSTABLE CHIMNEY

METAL FIRE STOP

Z.C. CABINET

Advertising