SECTION III

PRE-FAB INSERT INSTALLATION

The Model 81 may be installed into any UL listed pre-fabricated fireplace that is large enough
to accept it.

NOTE:

When installing Model 81 into a Pre-Fab Zero-Clearance fireplace, a UL-1777

LINER must be installed the Full Length of chimney and attached to flue exit of insert.

NOTE: The ash lip, smoke baffle and smoke shelf of pre-fab fireplace may be removed if
necessary to provide room for these models. Any other alteration to unit will void ALL New
Buck Corporation responsibility and liability. The warning label below must be attached to
back of fireplace.

NOTE: Plug power cord into a 115V AC outlet. Set switch to “Manual” and rheostat to
“High” position to ensure motor operates properly. Route power cord to prevent damage to
cord insulation from heat and sharp objects. Keep cord out of way of traffic to prevent damage
caused by tripping, etc.


NOTE: DO NOT BLOCK ANY EXISTING LOUVERS OR VENTS ON EXISTING
PRE-FAB WITH ANY TRIM PANELS FOR MODEL 81.

Except for “NOTES” above, please follow instruction of masonry installation, Section II.

Instruction
Minimum clearances for stove
Minimum clearances for floor protector







WARNING:

This fireplace must be

restored to it’s original condition for safe use
if the fireplace insert is removed.