SECTION VIII

TROUBLESHOOTING

PROBLEM

1. Sluggish heater















2. High Fuel

Consumption









3. Back puffing






4. Smoke rollout when

heater door is opened


POSSIBLE CAUSE

1. Obstruction in chimney

2. Improperly sealed trim kit

or direct connect kit






3. Wet or unseasoned wood

being burned.

4. Poor chimney draft




1. Improper regulation of

draft or inlet air





2. Improper door fitting



1. Gusts of Wind





1. Wind gusts blowing down

the chimney




2. Opening heater door too

fast

SOLUTION

1. Check for and remove

obstruction

2. (a) Check trim kit gasketing

seal to fireplace and gasket
as necessary to seal unit.
Gasket under front bottom of
stove if needed. (b) Check
seal if direct connect and
correct

3. Burn dried natural seasoned

hard wood

4. Improper chimney height or

wrong size flue is being
used. Cooler temperatures
caused by external chimney


1. Close inlet air control as

much as possible to maintain
desired heat output. Check
gaskets, reinstall fiberglass
gasket around doors and
glass as necessary

2. Check door gasket, check

adjustment of door latch,
check door hinges


1. Smoke shelf in chimney is

filled with creosote & ash.
Chimney may need wind
diverter. Raise chimney for
better draft


1. Smoke shelf in chimney is

filled with creosote & ash.
Chimney may need wind
diverter. Raise chimney for
better draft

2. Open air control. Crack door

for 15 seconds before fully
opening door

Page 33