Final check – New Buck Corporation 81 User Manual

Page 30

Advertising
background image

(a) Chimney pipe is 3' higher than roof at point where it penetrates roof.

(b) Chimney pipe height is at least 2' higher than any part of roof within 10' of chimney.
(See Page 27, Figure 12).

4. Next, install a New Buck Corporation chimney connector to flue of heater or use 3 “Ell”

brackets and secure to top of heater and pipe.

5. Using single wall chimney connector, connect heater to chimney by following manufac-

turer’s installation instructions exactly. (See Figure 13).






















Figure 13

FINAL CHECK

1. Recheck specified clearances.

2. Remove all foreign material from firebox area.

3. Open primary air draft.

NOTE: Plug power cord into a 115V AC outlet. Set switch to “Manual” and rheostat to
“High” position to ensure motor operates properly. Route cord to prevent damage to cord
insulation from heat and sharp objects. Keep cord out of way of traffic to prevent damage
caused by tripping, etc.

CHIMNEY CONNECTOR

SINGLE WALL PIPE

CEILING SUPPORT BOX