FEATURES & OPERATING CONTROLS (continued)

3

9

HI-LIMIT THERMOSTAT

Provides over-temperature protection by de-energizing HEATING
ELEMENTS should oil temperature exceed factory pre-set limits.

10 TEMPERATURE CONTROL

THERMOSTAT

Controls oil temperature. Range: 250ºF (121ºC)
375ºF (191ºC)

11


DRAIN VALVE LEVER

Opens and closes the DRAIN VALVE:
Turn counterclockwise (vertical) to OPEN
Turn clockwise (horizontal) to CLOSE

12 POWER OUTLET BOX

Electrical service connection TERMINAL BLOCK located here.

13

OIL FILTER RESERVOIR

Collects oil from FRYPOT for filtering or disposal.
Holds filter screen, filter paper & filter paper holder.

14

FILTER PUMP MOTOR
RESET BUTTON
(located at rear of motor)

FILTER PUMP MOTOR is equipped with an overheating
protection device.
RESET must be performed manually. Allow motor to cool for
approx. 30 min, then firmly press the red button.

15 LIFT

CRADLE

Lowers fry basket into frypot during cook cycle. Automatically
raises from frypot at end of cook cycle

16 FRY

BASKET

Holds product to be cooked.

17 LIFT

MOTOR

Raises/lowers LIFT CRADLE. Accessible for lubrication thru
access plate in rear panel.

18 DRIP

PAN

Collects liquids that accumulate on top of fryer section of
Ventilator Hood models (WVAE-…).

WARNING:

FIRE HAZARD / HOT OIL

The HI-LIMIT THERMOSTAT is a FIRE PROTECTION DEVICE.

If tripping persists, clean debris from the space between the

hi-limit bulb and the element to enhance oil flow and facilitate reset.

Otherwise, contact your authorized Wells Service Agent for repairs.

DO NOT ATTEMPT TO BYPASS OR HOLD IN THE BUTTON OF

THE HI-LIMIT THERMOSTAT. A SERIOUS FIRE MAY RESULT.

WARNING

363

300

07

OpM

anual

for

W

F

AE

-55F

/FS

Ele

c

tr

ic Frye

r

For units equipped with OPTIONAL FILTER WAND

W1 HEATER INTERLOCK SWITCH Disables heating element any time drain valve is not closed.

W2 3-WAY VALVE HANDLE

HORIZONTAL directs output of filter pump to filter wand.
VERTICAL directs output of fliter pump to frypot.

W3 QUICK DISCONNECT MALE

FITTING

Filter wand connects to this fitting.

W4 FILTER

WAND

Used to wash down sides of frypot, or to direct oil to disposal
container.

W1

W2

W3

11

W4

Advertising