Server Properties Configuration

Manual Documentation Number: ESP901-902-3704

Chapter 5

35

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com

B&B Electronics Ltd – Westlink Commercial Pk – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com

Flow Control

The Flow Control setting must match the requirements of the serial
device connected.

N

N

o

o

t

t

e

e

:

:

Select None when setting the port as RS-485 or 4-wire RS-422.

TCP/UDP Protocol

Select

TCP

(Transmission Control Protocol) or

UDP

(User Datagram

Protocol) protocol. If the application does not require a UDP
connection, select TCP. TCP guarantees reliable communication with
error checking whereas UDP provides faster transmission.

UDP Mode

When UDP mode is chosen the

Serial timeout

,

TCP alive timeout

,

Connection mode

,

Connection at

,

Max connection

and

Remote IP address

fields are replaced with the following

four fields:

Destination IP address range

,

Port number

and

Source IP address range

. In this mode the server can be

configured to broadcast data to and receive data from multiple
IP addresses. Four IP address range fields are provided.

Figure 32. The Server UDP Configuration Screen

Serial Timeout

Default for the

Timeout

property is 0, or no timeout. Setting

Timeout

to any value between 1 and 65535 seconds activates it. If

Timeout

is

set to 5 seconds and the

Serial Server

is configured as a

Server

, the

Client

makes a connection and communications starts. If

Server Properties Configuration

36

Chapter 5

Manual Documentation Number: ESP901-902-3704

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com

B&B Electronics Ltd – Westlink Commercial Pk – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com

communications are ideal for 5 seconds the

Serial Server

will reset and

make itself available for another client connection.

TCP Alive Timeout

The

Serial Server

monitors TCP activity. If TCP activity stops for the

length of time specified in this field the connection will be closed. This
field can be set to any value between 0 and 255 minutes. If zero, or no
value, is entered into this field the server will not disconnect.

Connection Mode

The Connection Mode field has three options:

Server

,

Client

and

Client (no heartbeat).

When

Client

or

Client (no heartbeat)

is

selected

the Connection at

field automatically becomes active

(allowing the user to select

Power up

or

Data Arrival)

.

• When using the

Virtual COM Port

feature, select

Server.

• When using a

TCP

or

UDP Socket

program, select

Server

.

• When using

Paired Mode

communication between two serial

servers set up one as a

Client

and the other as a

Server

.

• When connecting to a server that does not support

Heartbeat

,

select

Client (no Heartbeat).

Delimiter HEX 1 and Delimiter HEX 2

These fields allow the user to enter two ASCII characters (in hex
format) that delimit the beginning and end of a message. When a
message with both these delimiters is received at the serial port, the
data contained in the serial buffer is placed in an Ethernet packet and
sent out the Ethernet port. If only Delimiter 1 is set (Delimiter 2 is zero
or blank), upon receiving Delimiter 1 the ESP901/902 will put all the
data in the serial buffer in an Ethernet packet and send it out the
Ethernet port. If serial data greater than 1 kilobyte is received it will
automatically be placed in an Ethernet packet and sent out the Ethernet
port .

Force Transmit

This field allows the user to set a maximum time limit between
transmissions of data. The value set in this field multiplied by 100 ms
determines the Force Transmit time. When the elapsed time reaches the
time configured in this field, the TCP/IP protocol will pack the data
currently in the serial buffer into a packet and send it out the Ethernet
port.