B&B Electronics Vlinx Serial Servers ESP902E User Manual

Page 9

Advertising
background image

Introduction

Manual Documentation Number: ESP901-902-3704

Chapter 1

7

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com

B&B Electronics Ltd – Westlink Commercial Pk – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com

Step 5:

Re-enter

Server Properties

to verify the changes have taken

effect, or to view/change the configuration of other ports. Each
port must be configured separately.

Install Virtual COM Ports on PC

Step 1: From the

Windows Start

menu, run the

Install Virtual COM

Ports

utility included with the VLINX software,

Step 2: Search for all servers on the network

Step 3: Select a port and map it to an unused COM port (e.g. Port 15).

Configure it for TCP protocol and the appropriate IP address
(determined in the last section).

Figure 4.

Configuring the Virtual COM Port

Check Communications

Step 1: From the

Windows Start

menu, run

HyperTerminal

Step 2: Configure

HyperTerminal

to connect using the COM port

configured in the last section (e.g. Port 15).

Step 3: Set

Baud Rate

,

Data/Parity/Stop

, and

Flow Control

to match

the configuration of the serial device connected to the

Serial

Server

serial port.

Step 4: Communications with the serial device should now be

operational.

Introduction

8

Chapter 1

Manual Documentation Number: ESP901-902-3704

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com

B&B Electronics Ltd – Westlink Commercial Pk – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com

Advertising