B&B Electronics Vlinx Serial Servers ESP902E User Manual

Page 33

Advertising
background image

Using Console Mode

Manual Documentation Number: ESP901-902-3704

Chapter 9

55

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com

B&B Electronics Ltd – Westlink Commercial Pk – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com

C

C

h

h

a

a

p

p

t

t

e

e

r

r

9

9

:

:

U

U

S

S

I

I

N

N

G

G

C

C

O

O

N

N

S

S

O

O

L

L

E

E

M

M

O

O

D

D

E

E

Before the

Serial Server

is installed on a LAN the

Console Mode

can

be used to change the settings from the defaults. The

Serial Server

is

shipped in the

RS-232 Mode

.

Connect a crossover (null modem) cable

between the COM port on the computer and the appropriate serial port
on the

Serial Server

.

N

N

o

o

t

t

e

e

:

:

See Chapter 5 for details of each Server Property Settings.

Console Mode Setup

Step 1: Apply power to the

Serial Server

. The power and ready LED

will light.

Step 2: Using a VT100 Terminal emulation program (typically

HyperTerminal

in Windows) open the computer COM port

connected to the

Serial Server

(via an RS-232 crossover

cable).

Step 3: In the HyperTerminal

Port Settings

window set:

o Baud rate: 9600
o Data bits: 8
o Parity: None
o Stop bits: 1
o Flow control: None
Click

OK

Step 4: Ensure all the DIP switches are in the ON position.

Step 5: To view the

Configuration Menu

, press the

space bar

. The

menu will appear within a few seconds.

Using Console Mode

56

Chapter 9

Manual Documentation Number: ESP901-902-3704

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com

B&B Electronics Ltd – Westlink Commercial Pk – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com

Navigating the Configuration Menus

There are six

Console Mode

screens:

Server

,

Network

,

Serial Mode

,

Operation

,

Monitor

and

Configuration

.

Tab

,

Back Space

and

arrow

keys can be used to highlight the desired function on the screen list.
Pressing

Enter

moves the cursor to the first field with the current

screen. The configuration fields can be changed by pressing

Enter

and

selecting from the list that appears. The

Escape

key moves the cursor

back to the screen list. Pressing the

Space Bar

refreshes the page.

Figure 50.

Console Mode Configuration Screens

Advertising
This manual is related to the following products: