B&B Electronics Vlinx Serial Servers ESP902E User Manual

Page 28

Advertising
background image

Installing Virtual COM Port

Manual Documentation Number: ESP901-902-3704

Chapter 6

45

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com

B&B Electronics Ltd – Westlink Commercial Pk – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com

Figure 41. The Windows Logo Testing Window

This XP feature simply indicates that these drivers have not yet
undergone the Microsoft testing procedures required to use the
Windows XP Logo on the packaging. Driver compatibility is not
affected.

Step 4: Click

Continue Anyway

to proceed with the installation.

The Protocol TCP/UDP, IP Address, and Port Number will mirror the
settings of the selected serial server.

Step 5: After setting all

Serial Server

serial ports as virtual COM

ports, click

Cancel

on the

Found Server

form.

N

N

o

o

t

t

e

e

:

:

PCs may have hardware COM ports and devices such as Modems, IR

ports or USB based COM ports that are not currently connected Try
selecting a COM number above COM4 if problems occur.

The default

Flow Control

setting is

None

. RTS/CTS can be selected if

used by the application program and serial hardware. The

Serial Server

must be set to match.

Installing Virtual COM Port

46

Chapter 6

Manual Documentation Number: ESP901-902-3704

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com

B&B Electronics Ltd – Westlink Commercial Pk – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com

Matching the Serial Server and Virtual COM Port
Settings

The settings of the virtual COM ports in the

Device Manager

and the

Serial Server

Configuration Menu

must match. If the settings do not

match, the virtual COM ports will not work. If these settings are
changed in the

Device Manager

, it will only affect the operation of the

virtual COM port. It will not change the settings stored in the

Serial

Server

. Use the

ESP Manager

to change the

Serial Server

settings.

Step 1: Use Device Manager to

View New Ports

Confirm the virtual COM ports in the Device Manager.

Step 2: Double-click

Ports

to view the list of COM port numbers.

The installed Virtual COM port will be displayed as

VLINX ESP (COM

#)

.

Figure 42.

The Device Manager Window

Step 3: In the Device Manager select a

VLINX ESP COM#.

Double-

click it to bring up the

Properties

window.

Advertising
This manual is related to the following products: