Technical specifications, Controller software required, Product includes – Black Box COMPACT T1 MT850A User Manual

Page 408: Management, Network interface, Technical specifications -4

Advertising
background image

9-4

Compact T1 - Release 6.1

ISDN BRI Card

Technical Specifications

Technical Specifications

Controller Software Required

T1 Controller

l

Release 1.2.2 or higher is required

Product Includes

l

Configurable as Line Unit Line Terminal (LULT) or Line Unit Network Terminal
(LUNT)

l

Works with all standard Carrier Serving Area (CSA) loops - maximum 18,000 ft.
range (#26 AWG copper)

l

Line coding: 2

l

Line Rate: 160 Kbps (80 kbaud)

l

Front-panel multi-function LEDs provide out-of-Service, LOS/Self-test fail,
ES/SES detected, Sync, Loopback, and Normal indications

l

Interoperable with other standards-based ISDN BRI equipment

l

B1, B2, and 2B+D payload loopbacks supported

l

Maximum bridged tap length is 2.5 kft. (762 m)

l

Rear-accessed U-interface connections

Management

l

Standard ISDN SNMP MIB supported

Network Interface

l

3 DS0 mode: Uses 3 contiguous DSO channels per ISDN BRI channel on T1

Advertising