Bunn TB3Q-LP User Manual

Page 11

Advertising
background image

Page 11

SERVICE (cont.)

source. The indication must be:

a) 120 volts ac for two wire 120 volt models.

b) 200 to 230 volts ac for two wire 200 volt or 230

volt models.

8. Disconnect the brewer from the power source.

If voltage is present as described, reinstall the capillary

tube into the tank to the line 4.5" above the bulb, the

control thermostat is operating properly.

If voltage is not present as described, replace the

thermostat.

Removal and Replacement:

1. Disconnect the control thermostat wires.

2. Remove the thermostat capillary bulb by firmly

pulling-up on the capillary at the tank lid. This will

disengage the grommet from the tank lid.

3. Remove the one #6-32 screw securing the control

thermostat to the component bracket inside the

hood.

4. Slide the grommet to the line 4.5" above the bulb

on the new capillary tube.

5. Insert the capillary bulb through the hole in the

tank lid and press the grommet firmly and evenly

so that the groove in the grommet fits into the tank

lid.

6. Carefully bend the capillary tube so that the tube

and bulb inside the tank are in the vertical posi-

tion.

NOTE - The capillary tube must be clear of any electri-

cal termination and not kinked.

7. Using one #6-32 screw, secure the control thermo-

stat to the component bracket inside the hood.

8. Adjust the control thermostat as required.

CONTROL THERMOSTAT (cont.)

FIG. 11-1 CONTROL THERMOSTAT TERMINALS

41722 070209

FIG. 11-2 REPLACEMENT CONTROL THERMOSTAT

Advertising