Bunn TB3Q-LP User Manual

Page 17

Advertising
background image

Page 17

SERVICE (cont.)

INLET VALVES

Location:

The solenoid valve(s) are located inside the trunk

on the lower center part of the component bracket. So-

lenoids in the early models are located in the hood.

Test Procedures:

1. Check the solenoid valve for coil action. With "ON/

OFF" switch in the "ON' upper position press start

switch and listen carefully in the vicinity of the

solenoid valve for a" clicking" sound as the coil

magnet attracts.

2. Disconnect the brewer from the power source.

If the sound is heard as described and water will not

pass through the solenoid valve, there may be a block-

age in the water line before the solenoid valve or, the

solenoid valve may require inspection for wear, and

removal of waterborne particles.

If the sound is not heard as described, proceed to

#3.

3. Disconnect the brewer from the power source.

4. Connect a voltmeter across the solenoid terminals

(leave wires connected).

5. Connect the brewer to the power source. With the

"ON/OFF" switch in the "ON" upper position press

the start switch.

6. Check the voltage across the solenoid. The indica-

tion must be:

a) 120 volts ac for two wire 120 volt models and

three wire 120/240 volt models.

b) 200 to 230 volts ac for two wire 200 or 230 volt

models.

7. Disconnect the brewer from the power source,

If voltage is present as described, proceed to #8

If voltage is not present as described, refer to Wiring

Diagrams and check brewer wiring harness.

8. Check for continuity across the solenoid termi-

nals.

If continuity is present as described, reconnect the

white and black wire from the timer.

If continuity is not present as described, replace the

solenoid valve.

Removal and Replacement:

1. Disconnect the brewer from the power source.

2. Turn off the water supply to the brewer.

3. Remove the wires from the solenoid.

4. Disconnect the water lines to and from the solenoid

valve.

5. Remove the two screws securing the solenoid

mounting bracket to the component bracket.

6. Install new solenoid valve to the component

bracket.

7. Securely fasten the water lines to and from the

solenoid valve.

8. Refer to schematics when reconnecting the

wires.

FIG. 17-1 INLET VALVES

41722 070209