Bunn TB3Q-LP User Manual

Page 15

Advertising
background image

Page 15

SERVICE (cont.)
ON/OFF SWITCH-TB6/Q (Sweetner ½ Batch Option-TB3/Q)

Location:

The switch is located on the front control panel.

Test Procedure:

1. Disconnect the brewer from the power source.

2. Disconnect the wires from switch terminals.

3. Check for continuity across the center and right

and across center and left terminals in rows one

through four when the switch is in the oposite

position.

If continuity is not present as described, replace the

switch.

If continuity is present as described, replace the wires

the switch is operating properly.

Removal and Replacement:

1. Remove the wires from the switch terminals.

2. Remove the clips on the switch bezel inside the

hood and gently push the switch through the

opening.

3. Push the new switch into the opening from inside

the hood and secure into place by pressing the

bezel through the front of the hood. Make sure

the clips on the switch bezel are locked around

the switch housing and spread the clips to hold

the switch captive in the hood.

4. Refer to FIG. 15-2 when reconnecting the wires.

FIG. 15-1 NON LIGHTED ON/OFF SWITCH

P/N 03356.0003

Non Lighted

FIG. 15-2 ON/OFF SWITCH TERMINALS

FULL/OFF/HALF-TB3/TB3Q

LEFT/OFF/RIGHT-TB6

BLACK

GRAY

Optional

½ batch

WHI/VIO

PINK

optional

½ batch

WHI/VIO

UNSWEET/OFF/SWEET-TB3/TB3Q

w/SWEETENER & EMPTY DETECT

BLACK

WHI/GRN

WHI/VIO

BRN/WHI

WHITE

WHI/VIO

YELLOW

BLACK

BRN/BLK

41722 070209

Advertising