FIG. 20-1 DIGITAL TIMER

FIG. 20-2 DIGITAL TIMER

DIGITAL BREW TIMER (TB3Q & TB6Q)

SERVICE (cont.)

Location:

The timer is located in left side of the hood.

Test Procedure

NOTE: Do not remove or install wires while timer board

is installed. Pressure applied to one side may cause

damage to the board.

1. Disconnect the brewer from the power source and

remove the top cover.

2. With a voltmeter, check the supply voltage across

terminals TL1 and TL2. Connect the brewer to the

power source. Turn on the "ON/OFF" switch. The

voltage must be:

a) 120 volts ac for two wire 120 volt models.

b) 200 to 230 volts ac on two wire 200 volt or

230 volt models.

3. Disconnect the brewer from the power source.

If voltage is present as described, proceed to #4.

If voltage is not present as described, refer to the Wir-

ing Diagrams and check the wiring harness.

4. With a voltmeter, check the output voltage across

terminals TL1 and TL4. Connect the brewer to the

power source, turn on the "ON/OFF" switch and

press the "START" switch. The voltage must be:

a) 120 volts ac for two wire 120 volt models.

b) 200 to 230 volts ac for two wire 200 volt or 230

volt models.

If voltage is present as described, the timer is operat-

ing properly. If voltage is not present as described,

proceed to #5.

5. With a voltmeter, check the input start voltage

across terminals TL2 and TL5. Connect the brewer

to the power source, turn on the "ON/OFF" switch

and press the "START" switch. The indication must

be as follows:

a) 120 volts ac for two wire 120 volt models.

b) 200 to 230 volts ac on two wire 200 volt or

230 volt models.

If voltage is not present as described, refer to the

Wiring Diagrams and check the wiring harness to the

start switch.

If start voltage is present as described (but no output

voltage), replace the timer.

Removal and Replacement:

1. Remove the two #6-32 screws, lock washers and

spacers securing timer to bracket.

2. Disconnect all wires from the timer.

3. Refer to schematic and reconnect wires.

4. Install new timer to bracket with the two #6-32

screws, lock washers and spacers.

5. Adjust the timer as required.

Terminals:

J-2

½ batch connector

J-1

Multi batch (NOT USED IN TB SERIES)

SW-1 Programming Enable/Disable

TRM-1 White/Violet L1 from ON/OFF switch

TRM-2 White (Red) Neutral (L2)

TRM-3 White/Orange Start switch

TRM-4 White/Green Brew solenoid

TRM-5 White/Yellow Start switch

SW1

TRM-5

TRM-4

TRM-3

TRM-2

TRM-1

J-1

J-2

41722 070209