TROUBLESHOOTING (cont.)

Spitting or excessive steaming

(cont.)

Dripping from sprayhead

Water flows into tank continu-

ously (ON/OFF Switch "ON")

Water flows into tank continu-

ously (ON/OFF Switch "OFF")

Beverage overflows dispenser

2. Control Thermostat

1. Syphon System

2. Lime Build-up

CAUTION - Tank and tank com-

ponents should be delimed

regularly depending on local

water conditions. Excessive min-

eral build-up on stainless steel

surfaces can initiate corrosive

reactions resulting in serious

leaks.

3. Solenoid Valve

1. Timer

1. Solenoid Valve

1.Dispenser

2. Timer

3. Solenoid Valve

Refer to Service - Control Ther-

mostat for testing procedures.

The brewer must be level or

slightly lower in front to syphon

properly.

Inspect the tank assembly for

excessive lime deposits. Delime

as required.

Remove the solenoid valve and

clear any obstructions. Rebuild

or replace the valve if necessary.

Refer to Service - Timer for test-

ing procedures.

Remove the Solenoid Valve and

clean any obstruction. Rebuild

or replace the valve if necessary.

The dispenser must be com-

pletely empty before starting a

brew cycle.

Refer to Service - Timer for test-

ing procedures.

Remove the Solenoid Valve and

clean any obstruction. Rebuild

or replace the valve if necessary.

PROBLEM

PROBABLE CAUSE

REMEDY