Publication 1734-UM011D-EN-P - May 2011

48 Configure the Adapter for Direct Connection and Rack Optimization in RSLogix 5000 Software

6. To use redundancy in your system, check the Redundancy Enabled

checkbox so that a checkmark appears.

RSLogix 5000 software, version 11 and later, includes enable
redundancy. This example does not use redundancy.

7. Click OK.

Configure the I/O Modules

You now add the POINT I/O modules to the controller I/O configuration.
To do this, first add the local 1756-ENBT module to the I/O configuration.
Next, add the 1734-AENT adapter as a child of the 1756-ENBT module.
Then add the I/O modules as children of the 1734-AENT adapter.

Add the Local EtherNet/IP Bridge to the I/O Configuration

1. Select the I/O Configuration folder in the project dialog, and click the

right mouse button.

A dialog opens.

IMPORTANT

Click the Help buttons on the configuration dialog shown
in this section if you need assistance in selecting and setting
the parameters.