Safety

10

ESP Primer System Instruction Guide

p/n: 029-0810-01-0

Holding the primer ON for two (2) or three (3) seconds after a prime from
draft will clean out residue in the primer.

DO NOT run the primer over forty-five (45) seconds. If prime is not achieved
within 45 seconds, stop and look for causes (air leaks or blocked suction
hoses).

❑ Always use caution when handling or disposing of propylene glycol.
DO NOT USE ETHYLENE GLYCOL.
❑ DO NOT allow coolant to discharge to the ground. Review your departmen-

tal and/or local environmental regulations regarding the use of and disposal
of propylene gylcol coolants.

❑ Always follow the manufacturer’s recommended instructions on the label

affixed to the container.

Advertising