Cold Weather Starting Aids

If your telehandler is equipped with a block and grid heater, the following applies:

• Grid heater is located inside the induction manifold.

• Grid heater is triggered by temperature sensor located on engine.

• At start-up, temperature sensor on engine will detect if grid heater is needed.

Follow normal start-up procedure.

• A second battery is added for additional cold-cranking capacity. (6036 Before

S/N 0160039338 excluding 0160024571 & 0160037911, 6042 Before S/N
0160039075, 8042, 10042 & 10054 Before S/N 0160040220 excluding
0160039850, 0160040126 thru 0160040129 & 0160040171)

WARNING

ENGINE EXPLOSION. If your telehandler is equipped with a cold start aid, do
not spray additional ether into air cleaner. If machine is not equipped with cold
start aid, follow instructions listed in the engine manual supplied with the
telehandler.