Maintenance Schedule

1.

Check all hardware after the first 5 hours of use, then follow the maintenance schedule.

Fluid Levels

1.

MBW #01058---- 6-Pack (8 oz bottles)
MBW #17320---- 1 quart (32 oz)

Engine Maintenance

Refer to the engine owner’s manual for maintenance
intervals and procedures.

Cleaning Plate

Remove any excess debris which may get into the housing
of the unit.

SYSTEM

MAINTENANCE

EACH

USE

EVERY 50

HOURS

EVERY 100

HOURS

EVERY 250

HOURS

YEARLY

Engine

Refer to engine operator/owner manual

X

Clean cooling fins

X

X

Belts

Check for wear and retighten

X

Exciter

Check oil level

X

Check for oil leaks

X

Change oil

X

X

Tighten Bolts

1

X

X

Hydraulics

Check level and refill

X

Hardware

Check and tighten as needed

1

X

X

Shockmounts

Check for cracks or tears

X

X

SYSTEM

FLUID VOLUME

RECOMMENDED OIL

Exciter

GPR99

32 oz. (0.95 Liter)

MBW Ground Pounder

®

Exciter Oil

1

GPR135

32 oz. (0.95 Liter)

MBW Ground Pounder

®

Exciter Oil

1

Hydraulic Oil

GPR99

5 oz. (.24 Liter)

Chevron AW ISO32 or Rykon 32

GRP135

5 oz. (.24 Liter)

Chevron AW ISO32 or Rykon 32