13 troubleshooting – Lukas LSI 55 User Manual

Page 19

Advertising
background image

19

13 Troubleshooting

If the defects cannot be repaired, contact an authorised LUKAS dealer or the
LUKAS service department.
The address of the LUKAS service department is:
LUKAS Hydraulik GmbH, Weinstraße 39, D-91058 Erlangen; PF 2560, D-91013
Erlangen Kundendienst Tel 09131/698 348; Fax 09131/698 353.

Trouble

Check

Cause

Remedy

Hoses cannot be
coupled

Pressurized

Relieve pump
pressure

Blades move slowly
or by jerks when
actuated

Hoses correctly
connected, power
pack operating

Air in the hydrallic
system

Thorougly vent
pump unit

No pressure build-up

Insufficient oitl in
the hand or motor
pump. Pump not
ventilated after oil
change

Refill oil an
ventilate the
system

Star grip does not
return to the middle
position when
released

Damage of the
return spring for
resetting, fouling

Repair by an
authorized dealer
or directly by
LUKAS

Oil leakage out of
hoses or hose fittings

Untightness,
possible
damages

Replace hoses

Surface of the
hydraulic hoses is
dissolved

Contact wirh
aggressive media

Replace hoses

Blades spread up at
tips to a gab of more
than 3 mm (LSI511
and LSI55) and more
than 5 mm (LSI501
and LSI530)
respectively

Torque of the
central bolt nut is
insufficient

Retighten, see
chapter 12.2.1

Leakages: leaks at
the piston rod

Defective piston
rod seal

Changing the
seals by an
authorized dealer
or directly by
LUKAS

Advertising