Caution – Snorkel TB85J Fixed Axle CE User Manual

Page 27

Advertising
background image

Chapter 6 – Controls

TB80/TB85J Fixed Axle – 0112823EE

23

Hydraulic System Warm-up Switch
Some engines may have a hydraulic fluid warm-up sys-
tem. This system may be used to warm the hydraulic
fluid when the ambient temperature is below 0°C (32°F)
and boom movement is sluggish because of cold fluid.

There is a toggle switch for the warm-up system on the
lower control panel and one on the left side of the upper
control panel.

The engine must be running and the switch used to turn
the system on, must be at the same location that the
engine was started. For example, if the engine was started
from the lower controls, the warm-up switch at the lower
controls must be used for the system to operate.

Machine functions are not operational while using the
hydraulic warm-up system.

Circuit Breaker Reset Buttons

The lower control panel electrical system has a circuit
breaker for the lift/swing circuit (refer to Figure 6.2). There
is a reset button for the circuit breaker on the bottom of
the lower control panel

The wiring box (refer to Figure 6.3) electrical system has
a circuit breaker for the main, run, and throttle circuits.
There is a reset button for each circuit breaker on the
front of the wiring box.

Figure 6.3 – Wiring Box

The upper control panel (refer to Figure 6.4) has a circuit
breaker for the main and drive circuits. The circuit breaker
reset buttons are on the front of the upper control panel.

Figure 6.4 – Upper Control Panel Front

The circuit breakers protect the electrical wiring and com-
ponents from electrical overload in case of a short circuit
or other fault.

A

Caution

A tripped circuit breaker indicates a malfunction in
the electrical system. Component damage can re-
sult if the cause of the malfunction is not corrected.
Do not operate the aerial platform if the circuit
breaker trips repeatedly.

Push the button to reset the circuit breaker.

Upper Controls

The upper controls (refer to Figure 6.5) are located on the
control panel at the platform. Boom, platform, and drive
functions can be operated from the upper controls. The
following controls are located on the upper control panel.

• Start switch
• Emergency stop button
• Boom joystick
• Drive joystick
• Drive range switch
• Steer mode switch
• Jib articulation switch – TB85J only
• Platform level switch
• Platform rotate switch
• Boom extend/retract joystick
• Engine/emergency power switch
• Throttle switch

Circuit Breaker Reset Buttons

Start Switch

Circuit Breaker Reset Buttons

Advertising
This manual is related to the following products: