1.9 MACHINE SETUP MENU

The Machine Setup Menu is used to configure the Load
Sensing System for application on a particular JLG model,
and select the desired force units (i.e. pounds or kilo-
grams). In addition, the technician can trigger the LSS
Module to restore Defaults to all Personalities Parameters
by changing the MODEL to any other selection, and then
re-selecting BOOM LIFT.
Note that Diagnostics and Personalities Menus change
based on MODEL Parameter (some displays are sup-
pressed).
To access the Machine Setup Menu, use the LEFT and
RIGHT Arrow keys to select MACHINE SETUP from the
Top Level Menu. Press the ENTER key to view the menu.
Press the LEFT and RIGHT Arrow keys to view the dis-
plays.
The following table details the structure of the Machine
Setup Menu, and describes the meaning of each parame-
ter.

1.10 CALIBRATION MENU

The Calibration Menu is used to zero the Empty Platform
weight.
To access the Calibration Menu, use the LEFT and RIGHT
Arrow keys to select CALIBRATION from the Top Level
Menu. Press the ENTER key to view the menu.

NOTE: The Calibration Menu is not available in Access

Level 2.

Upon entry to the Calibration Menu, the LSS Module shall
communicate to the Analyzer:

CALIBRATE:
YES:ENTER, NO:ESC

Pressing the ESC key will return the user to the top level
menu and not disturb the prior calibration information.
Pressing the ENTER key will confirm that the platform is
empty (except for factory-installed options outside the
Rated Load). The LSS Module will calculate the total of all
load cell readings and ensure that the total is greater than

Table 1-4. Machine Setup Menu

Parameter

(Displayed on

Analyzer 2

nd

Line)

Parameter Value

(Displayed on

Analyzer 2

nd

Line)

Description

MODEL:

= BOOM LIFT
=4069LE
=3369LE
=500RTS
=260MRT

Displays/adjusts Model Selec-
tion. Must be set to BOOM LIFT
for this application.

UNITS:

=LBS
=Kg

Displays/adjusts global force
units