SECTION 3 - SERVICE - ELECTRIC POWERED BOOM LIFTS

3124287

– JLG Lift –

3-7

form (do not confuse the Host Control System and
LSS Module’s Analyzer Connections).

Enter the Access Level 1 Password (33271). Next,
proceed to the MACHINE SETUP, LOAD sub-menu
and select “2=CUTOUT PLT”. Press the RIGHT
ARROW to view the MACHINE SETUP, LOAD TYPE
sub-menu. Set it to “1=4 UNDER BASKET” to select
the Load Sensing System with four Shear Beam
Load Cells beneath the platform. At this point, it is
likely that the Host Control System’s Visual and
Audible Warnings for the Load Sensing System will
be active (since the LSS Module is un-calibrated).

11. Perform a Calibration of the Load Sensing System.

Refer to the Calibration procedure in this manual to
prepare the Load Sensing System for use.

3.3 CALIBRATION

Procedure

1. Plug the JLG Analyzer into the LSS Module and

enter the Access Level 1 Password. Do not confuse
the Host Control System and LSS Module’s Analyzer
Connections. The Host Control System’s connection
is mounted beneath the Platform Console Box, and
the LSS Module’s connection hangs from a short
harness near the module. Proceed to the ACCESS
LEVEL menu and enter the Access Level 1 Pass-
word (33271).

2. Level the Platform. The platform should be approxi-

mately level for calibration. Level the platform from
Ground Control (if necessary) to within +5 degrees.

3. Configure the LSS Module for Boom Lift mode and

Desired Units. Proceed to the LSS Module’s
MACHINE SETUP, MODEL sub-menu and select
“MODEL=BOOM LIFT”. Press the RIGHT ARROW to
view the Units Selection. Select “UNITS=LBS” for
platform load measurement in Pounds, and
“UNITS=KG” for measurement in Kilograms.

4. Remove everything except JLG Accessories from

the Platform. Empty the platform to allow the Load
Sensing System to record its weight during calibra-
tion. All tools, debris, and customer-installed devices
shall be removed. Permanently-fixed JLG Accesso-
ries shall remain and their contribution toward Rated
Load will be accounted for in the next step.

5. Configure the LSS Module for JLG Accessories. The

contribution of each permanently-fixed JLG Acces-
sory toward Rated Load must be determined. JLG
Accessories are decaled with their effective contribu-
tion toward Rated Load. If this decal is missing, ref-
erence the appropriate manual for the JLG
Accessory or consult the table within this manual.
Once determined, the contributions of all perma-
nently-fixed JLG Accessories mounted in the plat-
form of the vehicle shall be added together and
entered in the Analyzer’s PERSONALITIES, ACC’Y
display (using the proper units).

6. Execute a Calibration via the JLG Analyzer. Proceed

to the Analyzer’s CALIBRATION top level menu and
press ENTER. Press ESC to abort a calibration or
ENTER to calibrate (tare). If successful, the Analyzer
will display “COMPLETE”. If unsuccessful, a mes-
sage will be displayed that will help lead to a resolu-
tion (reference the Troubleshooting section of this
manual). Press ESC to return to the top level menu.