SECTION 2 - PROCEDURES

3120737

– JLG Lift –

2-23

2. The Torqlink™ inner housing bearing/bushing (13)

can now be pressed into its counterbore in housing
(18) flush to 0.03 inch (.76 mm) below the housing
wear plate contact face. Use the opposite end of the
bearing mandrel that was used to press in the outer
bearing/bushing (19).

3. Press a new dirt and water seal (20) into the housing

(18) outer bearing counterbore.

The Torqlink™ dirt and water seal (20) must be pressed in
until its’ flange is flush against the housing.