18 pressure setting procedures, Lift relief for non proportional control machines, Steer adjustment for proportional control machines – JLG 3246E2 ANSI Service Manual User Manual

Page 46: Pressure setting procedures -32

Advertising
background image

SECTION 2 - PROCEDURES

2-32

– JLG Lift –

3120737

2.18 PRESSURE SETTING PROCEDURES

NOTE: Make all pressure adjustments with motor operating

and hydraulic oil at normal operating temperature. In
addition, all functions must be operated from the
platform control station in order to achieve full pump
speed. It may be necessary to use an assistant to
adjust the pressure settings while operating the func-
tions from the platform control station.

Lift Relief for Non Proportional Control

Machines

1. Install a pressure gauge at gauge port MP, located at

the inside top of the valve body. The port is identified
by a stamping on the valve body.

2. Disconnect the hose from valve port 3, then plug the

hose and the valve port.

3. From the platform control station, activate the Lift Up

function by pressing the LIFT switch and activating
the controller to the full forward position.

4. Adjust Lift Relief to value in the Pressure Settings

Chart.

5. Shut down hydraulic system and remove pressure

gauge.

Steer Adjustment for Non Proportional

Control Machines

1. With pressure gauge at "MP" port on control valve

activate steer in either direction.

2. Adjust Steer Relief to value in the Pressure Settings

Chart.

Main Relief Pressure Switch for Non

Proportional Control Machines

1. Install a pressure gauge at gauge port MP, located at

the bottom front of the valve body. The port is identi-
fied by a stamping on the valve body.

2. Disconnect the power from the drive valve on top of

the valve body.

3. Activate drive by moving the joystick to the full for-

ward position.

4. Adjust Main Relief to value in the pressure setting

chart.

5. Reinstall the electrical connections to the drive

valve.

Lift Relief Adjustments for Proportional

Control Machines

1. Install a pressure gauge at gauge port MP, located at

the inside top of the valve body. The port is identified
by a stamping on the valve body.

2. Disconnect the hose from valve port 3, then plug the

hose and the valve port.

3. From the platform control station, activate the Lift Up

function by pressing the LIFT switch and activating
the controller to the full forward position.

4. Adjust Lift Relief to value in the Pressure Settings

Chart.

5. Shut down hydraulic system and remove pressure

gauge.

Steer Adjustment for Proportional Control

Machines

1. With pressure gauge at "MP" port on control valve

activate steer in either direction.

2. Activate drive by pressing the drive switch and acti-

vating the controller to the full forward position.
While holding the controller, activate steer right and
check steer right pressure. If necessary, adjust steer
right pressure to value in the Pressure Settings
Chart.

3. Activate drive by pressing the drive switch and acti-

vating the controller to the full forward position.
While holding the controller, activate steer left and
check steer left pressure. If necessary, adjust steer
left pressure to value in the Pressure Settings Chart.

Main Relief and High Drive Pressure Switch

for Proportional Control Machines

1. Install a pressure gauge at gauge port MP, located at

the bottom front of the valve body. The port is identi-
fied by a stamping on the valve body.

2. Close the steer valve completely by turning clock-

wise.

3. Once the steer valve is closed activate the steer

switch in either direction until the steer cylinder bot-
toms out.

4. Adjust your Main Pressure to value in the Pressure

Settings Chart.

5. Once you have adjusted your main pressure be sure

and reset your steer pressure back to value in the
Pressure Settings Chart.