19 limit switch adjustment, Elevation switch, 20 door adjustment – JLG 3246E2 ANSI Service Manual User Manual

Page 49: Limit switch adjustment -35, Quick welder™ installation -35

Advertising
background image

SECTION 2 - PROCEDURES

3120737

– JLG Lift –

2-35

2.19 LIMIT SWITCH ADJUSTMENT

Elevation Switch

On the 1532E2/1932E2/3246E2 there is a platform limit
switch located at the head of the lift cylinder on the middle
inside arm. When activated, the switch cuts out the Drive
function if the Pothole Protection is not set. The cut out
heights are set at a maximum of the following:

2.20 DOOR ADJUSTMENT

NOTE: There is an eccentric bolt on the hinge side under-

neath of each door. If the door needs raised or low-

ered this can be accomplished by turning these

bolts. Adjust these bolts to the outside to avoid drag

on the pothole protection system when the door is

opened.

NOTE: There are two bolts on top of each door in the cor-

ners. These are designed to take the weight off the

pothole protection system and distribute it around

the underside of the frame if the machine were to be

run over any uneven terrain or dropped into any

void. The clearance between the top of the bolts and

the frame should be a min. of 3/4 in to a max. of 1 1/

2 in.

WELDER

TERMINAL

CONNECTOR

FIRE

EXTINGUISHER

Figure 2-11. Quick Welder

Installation

Model

In

m

1532E2

84

2.1

1932E2

104

2.6

3246E2

112

2.8

Advertising