JLG 3246E2 ANSI Service Manual User Manual

Page 57

Advertising
background image

SECTION 2 - PROCEDURES

3120737

– JLG Lift –

2-43

5

(FUNCTION CUTOUT)

0

1

No function cutout installed.

Overload switch for French, Japanese machines. — Cuts out

all functions. Sounds

platform alarm for two seconds on, two seconds off, while operator tries to perform the
function that has been cut out (provided the platform alarm is installed).

0

6

(GROUND ALARM)

0

1

2

3

No ground alarm installed.

Descent alarm. — Sounds when LIFT DOWN is active.

Travel alarm. — Sounds when DRIVE function is active.

Motion alarm. — Sounds whenever the DRIVE, LIFT or DECK function is active.

0

7

(DRIVE CUTOUT)

0

1

No drive cutout switch installed.

Cuts out DRIVE when deck is elevated above a predetermined elevation (varies with
machine model).

0

8

(ARM GUARDS))

0

1

No arm guard cutout.

European (CE Specification) machines — LIFT DOWN cutout must activate when the
gap between the arms is 5 in. to 8 in. (13 cm to 20 cm). Here it will cut out LIFT DOWN
and sound the platform alarm for 1/2 second on, 1/2 second off, and repeat this for
three seconds. After three seconds, the operator must re-select the LIFT function and
continue to operate LIFT DOWN. If the wires to the limit switch used to detect the deck
height are cut or the switch has failed, the platform alarm will sound as mentioned. The
operator can re-select the LIFT function and then LIFT DOWN for ten seconds, at
which time it will cut out again and the process must be repeated.

0

9

(Flash Codes)

0

1

2

3

LED Only

LED and lamps in platform control box

LED and alarm

LED, lamps in control box and alarm

0

Table 2-6. Machine Configuration Programming Information

Configuration Digit

Number

Description

Default Setting

Before

Programming

Advertising