9-27

G10-55A, G12-55A

Electrical System

441

168

18

Amber

Electrical

Potential

(Voltage)

Battery #1 Voltage Low—Data Valid but Below
Normal Operational Range—Moderately
Severe Level

442

168

16

Amber

Electrical

Potential

(Voltage)

Battery #1 Voltage High—Data Valid but Above
Normal Operational Range—Moderately
Severe Level

449

157

0

Red

Injector

Metering Rail 1

Fuel Pressure High—Data Valid but Above Normal
Operational Range—Moderately Severe Level

451

157

3

Amber

Injector

Metering Rail 1

Injector Metering Rail #1 Pressure Sensor Circuit—
Voltage Above Normal, or Shorted to High Source

452

157

4

Amber

Injector

Metering Rail 1

Injector Metering Rail #1 Pressure Sensor Circuit—
Voltage Below Normal, or Shorted to Low Source

488

105

16

Amber

Intake Manifold

Manifold 1 Temperature—Data Valid but Above Nor-
mal Operational Range—Moderately Severe Level

489

191

18

Amber

Transmission

Output Shaft

Speed

Transmission Output Shaft Speed—Data Valid but
Below Normal Operational Range—Moderately
Severe Level

497

1377

2

Amber

Switch Circuit

Multiple Unit Synchronization Switch Circuit—Data
Erratic, Intermittent, or Incorrect

515

3514

3

Amber

Not Available

Sensor Supply 6 Circuit—Voltage above normal, or
shorted to high source

516

3514

4

Amber

Not Available

Sensor Supply 6 Circuit—Voltage below normal, or
shorted to low source

523

611

2

Amber

System code # 1

Diagnostic

OEM Intermediate (PTO) Speed switch Validation—
Data Erratic, Intermittent, or Incorrect

527

702

3

Amber

Circuit—Voltage

Auxiliary Input/Output 2 Circuit—Voltage Above
Normal, or Shorted to High Source

528

93

2

Amber

Switch—Data

Auxiliary Constrained Operation Curve Validation
Switch—Data Erratic, Intermittent, or Incorrect

529

703

3

Amber

Circuit—Voltage

Auxiliary Input/Output 3 Circuit—Voltage Above
Normal, or Shorted to High Source

553

157

16

Amber

Injector

Metering Rail 1

Pressure

Injector Metering Rail #1 Pressure High—Data Valid
but Above Normal Operational Range—Moderately
Severe Level

Fault

Codes

SPN

Codes

FMI

Codes

Lamp

Color

SPN

Description

Cummins Description

Advertising