Electrical System

9-30

G10-55A, G12-55A

1974

101

15

Amber/

Blink-

ing

Not Available

Crankcase Pressure—Data Valid But Above Normal
Operating Range—Least Severe Level

2185

3512

3

Sensor Supply 4 Circuit—Voltage above normal, or
shorted to high source

2186

611

4

Amber

System code # 1

Diagnostic

Sensor Supply 4 Circuit—Voltage Below Normal, or
Shorted to Low Source

2195

703

14

Auxiliary Equipment Sensor Input 3 Engine
Protection Critical—Special Instructions

2249

157

1

Amber

Injector

Metering Rail

1 Pressure

Injector Metering Rail 1 Pressure—Data Valid
but Below Normal Operational Range—Most
Severe Level

2272

27

4

Amber

Not Available

EGR Valve Position Circuit—Voltage Below Normal,
or Shorted to Low Source

2288

103

15

None

Not Available

Turbocharger 1 Speed—Data Valid But Above
Normal Operating Range—Least Severe Level

2311

633

31

Amber

Fuel Control

Valve #1

Fueling Actuator #1 Circuit Error—Condition Exists

2321

190

2

None

Engine Speed

Engine Speed / Position Sensor #1—Data Erratic,
Intermittent, or Incorrect

2322

723

2

None

Engine Speed

Sensor #2

Engine Speed / Position Sensor #2—Data Erratic,
Intermittent, or Incorrect

2349

2791

5

Amber

Not Available

EGR Valve Control Circuit—Current below normal or
open circuit

2353

2791

6

EGR Valve Control Circuit—Current above normal
or grounded circuit

2357

2791

7

Amber

Not Available

EGR Valve Control Circuit—Mechanical system not
responding or out of adjustment

2372

95

16

Fuel Filter Differential Pressure—Data Valid But
Above Normal Operating Range—Moderately
Severe Level

2373

1209

3

Amber

Exhaust Gas

Pressure

Exhaust Gas Pressure Sensor Circuit—Voltage
Above Normal, or Shorted to High Source