SECTION 6 - JLG CONTROL SYSTEM

3121623

– JLG Lift –

6-41

78

VACC not OK

Cause:

Solution: Usually it is a temporary anomaly due to a particular working condition. In case
the anomaly persists replace the inverter.

79

Incorrect start

Cause: Starting procedure not correct

Solution: Control the electric connections. Usually it is a temporary anomaly due to a
particular working condition. In case the anomaly persists replace the inverter.

86

Pedal wire KO

Cause:

Solution: Usually it is a temporary anomaly due to a particular working condition. In case
the anomaly persists replace the inverter.

93

Wrong set batt

Cause: With supply ON, the control test detected batteries not in conformity.

Solution: Replace the batteries with the original ones supplied by JLG.

94

Current sensor KO

Cause: Max current setup procedure active.

Solution: Contact JLG after sales dept.

99

Check up needed

Cause:

Solution: Contact JLG after sales dept.

Table 6-7. INVERTER Diagnostic trouble code chart